DL/T 645 + Modbus RTU
RS485 carries DL/T 645 and Modbus RTU at up to 115200 bps for EV charging and DC energy-management integration.
DIN-rail DC energy meter with external 75 mV shunt and 9–60 V DC auxiliary supply for EV charging.
RS485 carries DL/T 645 and Modbus RTU at up to 115200 bps for EV charging and DC energy-management integration.
Class 1.0 active energy accuracy for reliable DC energy measurement and monitoring in EV charging applications.
75 mV external shunt sampling supports primary-side currents up to 2000 A with configurable current settings, enabling flexible current-range configuration for different DC charging power levels.
6.4 kV 1.2/50 μs impulse and 4400 V/min AC withstand harden the meter for EV charging and DC distribution.
6+2-digit LCD displays DC energy, voltage, current and power for clear on-site monitoring.
Backlight turns red on overcurrent for immediate visual fault indication in DC metering.
Solutions for AC/DC charging, billing and charging platform integration.
Explore ApplicationDC/PV monitoring for inverters, storage systems and distributed energy monitoring.
Explore ApplicationRack, cabinet and distribution power monitoring for data center operations.
Explore Application| Voltage connection | DC 5–1000 V |
| Current connection | External shunt (75 mV) |
| Maximum current | 2000 A (75 mV shunt; 200 A default) |
| Auxiliary power supply | 9–60 V DC |
| Impulse constant | 1000 imp/kWh |
| Power consumption | ≤8 VA / ≤0.4 W |
| Active energy accuracy | Class 1.0 |
| Current accuracy | 0.5% |
| Voltage accuracy | 0.5% |
| Active power accuracy | 1.0% |
| Communication interface | RS485 |
| Protocol | DL/T 645, Modbus RTU |
| Baud rate | up to 115200 bps (default) |
| Display | LCD 6+2 |
| Overcurrent alarm | Backlight turns red |
| AC withstand voltage | 4400 V/min |
| Impulse withstand voltage | 6.4 kV 1.2/50 μs |
| Installation | 35 mm DIN rail, 2-module |
| Operating temperature | −25°C to +70°C |
| Humidity | ≤95% |
DIN-rail DC energy meter with external 75 mV shunt and 9–60 V DC auxiliary supply for EV charging.
External shunt sampling at 75 mV, supporting a primary-side current up to 2000 A (200 A default).
RS485 supports DL/T 645 and Modbus RTU dual protocols at up to 115200 bps.
Class 1.0 active energy accuracy, with 0.5% current and voltage accuracy and 1.0% active power accuracy.
9–60 V DC
No. DEM2D003 does not include an internal battery, multi-tariff functions or relay output. For these functions with a 9–60 V DC auxiliary supply, consider DEM2D103. DEM2D102 offers the additional functions with an 85–265 V AC/DC auxiliary supply.
Official DEM2D Series datasheet covering product overview, specifications, wiring and dimensions.