≤75 ms Communication Refresh
Specified RS485 communication refresh time of ≤75 ms for applications requiring timely meter-side data updates.
DEM2A302 is a single-phase, direct-connected DIN-rail energy meter for 1P2W systems, with a maximum current of 100 A. It supports RS485 communication with Modbus RTU and DL/T 645-2007 compatibility and a specified RS485 communication refresh time of ≤75 ms. Four TOU tariffs across eight time periods, external tariff switching and battery-backed RTC timekeeping are provided. The model is MID B+D certified by SGS UK.
MID

Specified RS485 communication refresh time of ≤75 ms for applications requiring timely meter-side data updates.
Class 0.5 active-energy measurement supports reliable monitoring and submetering applications.
Supports two-way RS485 communication compatible with Modbus RTU and DL/T 645-2007 for integration with compatible monitoring systems.
Supports single-phase 1P2W direct connection with a maximum current of 100 A, without requiring an external CT.
Supports forward, reverse, absolute-value, algebraic-sum and forward/reverse offset energy calculation modes.
Measures key electrical parameters and provides EEP self-diagnosis and configurable alarms with adjustable thresholds and delays.
Solutions for AC/DC charging, billing and charging platform integration.
Explore ApplicationDC/PV monitoring for inverters, storage systems and distributed energy monitoring.
Explore ApplicationBranch metering for buildings, factories, tenants and energy allocation.
Explore ApplicationRack, cabinet and distribution power monitoring for data center operations.
Explore Application| Connection type | Direct-connected, 1P2W |
| Meter format | Single-phase, 2P DIN-rail |
| Rated voltage | 120–230 V AC |
| Operating voltage range | 0.8–1.15 Un |
| Basic current (Ib) | 5 A |
| Minimum current (Imin) | 0.15 A (MID) / 0.25 A (IEC) |
| Maximum current (Imax) | 100 A |
| Rated frequency | 50/60 Hz |
| Power consumption | ≤2 W / 10 VA |
| Pulse constant | 1000 imp/kWh |
| Voltage accuracy | ±0.5% |
| Current accuracy | ±0.5% |
| Frequency accuracy | ±0.5% |
| Active power accuracy | ±0.5% |
| Reactive power accuracy | ±1% |
| Active energy accuracy | Class 0.5 |
| Reactive energy accuracy | Class 1 |
| Communication method | RS485 |
| Supported protocols | Modbus RTU and DL/T 645-2007 compatibility |
| Specified communication refresh | ≤75 ms (RS485 communication refresh condition only) |
| Fast Data Refresh | Applies to the specified RS485 communication refresh only; it is not waveform sampling rate or system latency. |
| Tariff function | Built-in RTC and TOU tariff metering; four tariffs and eight time periods by default |
| Dimensions | 36 × 94 × 62.4 mm |
| DIN rail | 35 mm standard DIN rail |
| Operating temperature | -40°C to +70°C |
| Humidity | ≤95%, non-condensing |
| Altitude | ≤2000 m |
| Protection rating | IP20 |
| Protective class | Class II |
| Overvoltage category | III |
| Rated impulse withstand voltage | 6 kV |
| Applicable standards | IEC 62052-11:2020, IEC 62053-21:2020, IEC 62053-24:2020 and EN 50470-3:2022 |
Yes. DEM2A302 is MID certified. Verify the applicable model scope on the YTL Certificates page or contact YTL for documentation.
DEM2A302 supports RS485 communication with Modbus RTU and DL/T 645-2007 compatibility.
It is the specified RS485 communication refresh time. It is not waveform sampling rate, system latency or control-loop response time.
Yes. DEM2A302 includes RTC and TOU tariff metering with four tariffs and eight time periods by default.
DEM2A302 uses direct 1p2w wiring. Follow the official model-specific wiring diagram and terminal markings.
DEM2A302 is suitable for solar PV, BESS, EV charging, building and industrial energy-monitoring projects using compatible RS485 systems.
Official DEM2A series datasheet covering product overview, specifications, wiring and dimensions.
Download PDFTell us your requirements and our team will provide a professional solution and quotation within 24 hours.