≤75 ms Communication Refresh
Specified RS485 communication refresh time of ≤75 ms for applications requiring timely meter-side data updates.
DEM3K202 is a 3P DIN-rail, CT/PT-operated 3P3W (Aron) / 3P4W energy meter designed for high-precision energy monitoring through external current and voltage transformers. It supports RS485 communication with Modbus RTU and DL/T 645-2007 compatibility, a specified communication refresh time of ≤75 ms, switched tariff input and Class 0.5s active energy accuracy. CT ratios up to 2000:1 and PT ratios up to 350:1 are supported. The meter has no internal battery, RTC or TOU schedule.
MID

Specified RS485 communication refresh time of ≤75 ms for applications requiring timely meter-side data updates.
Class 0.5s active-energy measurement in accordance with IEC 62053-21 supports high-precision energy monitoring through external CT/PT.
Supports RS485 communication with Modbus RTU and DL/T 645-2007 compatibility, with configurable baud rates from 9.6 to 115.2 kbps and addresses from 1 to 247.
CT ratio up to 2000:1 and PT ratio up to 350:1. Maximum combined CT × PT ratio of 350000:1 supports a wide range of transformer configurations.
Supports switched tariff input for dual-tariff applications. DEM3K202 has no internal battery, RTC or TOU schedule.
No internal battery, RTC or TOU schedule. Supports external switched tariff input only (two tariffs by default). Reduced component count simplifies long-term maintenance. For a battery-equipped TOU variant, see DEM3K302.
Solutions for AC/DC charging, billing and charging platform integration.
Explore ApplicationDC/PV monitoring for inverters, storage systems and distributed energy monitoring.
Explore ApplicationBranch metering for buildings, factories, tenants and energy allocation.
Explore ApplicationRack, cabinet and distribution power monitoring for data center operations.
Explore Application| Connection type | CT / PT (external current and voltage transformers) |
| Wire system | 3P3W (Aron) / 3P4W |
| Rated voltage (Un) | 3 × 57.7/100–230/400 V (3P4W); 3 × 100–400 V (3P3W) |
| Voltage tolerance | 0.8 to 1.15 Un |
| Frequency | 50/60 Hz |
| Current connection | CT (external current transformer) |
| Basic current (Ib) | 5 A |
| Minimum current (Imin) | 0.05 A |
| Maximum current (Imax) | 6 A |
| CT ratio | Up to 2000:1 |
| PT ratio | Up to 350:1 |
| CT × PT ratio (max) | 350000:1 |
| Power consumption | ≤2 W / 10 VA |
| Pulse constant | 10000 imp/kWh |
| Voltage accuracy | ±0.5 % |
| Current accuracy | ±0.5 % |
| Frequency accuracy | ±0.5 % |
| Active power accuracy | ±0.5 % |
| Reactive power accuracy | ±1 % |
| Active energy accuracy | Class 0.5s |
| Reactive energy accuracy | Class 1 |
| Communication interface | RS485 |
| Protocol | Modbus RTU and DL/T 645-2007 |
| Communication type | Bidirectional |
| Communication address | 1 to 247 |
| Baud rate | 9.6 / 19.2 / 38.4 / 57.6 / 115.2 kbps |
| Parity | None / Odd / Even |
| Specified communication refresh time | ≤75 ms |
| Display and controls | Backlit LCD, 500 ms refresh, page navigation and setting buttons |
| LED indicator | Red pulse LED |
| Metering functions | Energy, power, power factor and harmonic monitoring |
| Energy calculation | Forward, reverse, absolute-value, algebraic-sum and net-energy modes |
| Tariff function | External switched tariff input; default two tariffs |
| Diagnostics and alarms | EEP self-diagnostics and configurable monitoring alarms |
| Other functions | Local firmware upgrade, wiring check, screen saver, page filter and runtime-hour counter |
| Operating temperature | −40°C to +70°C |
| Ingress protection | IP20; install in an IP54 outdoor or IP51 indoor enclosure |
| Overvoltage category | OVC III |
| Protection class | Class II |
| Rated impulse withstand voltage | 6 kV |
| Applicable standards | IEC 62052-11:2020 / IEC 62053-21:2020 / EN 50470-3:2022 |
DEM3K202 is a 3P DIN-rail, CT-operated 3P3W (Aron) / 3P4W energy meter rated up to 6 A. It supports RS485 with Modbus RTU and DL/T 645-2007, with a specified communication refresh time of ≤75 ms. It supports switched tariff operation.
DEM3K202 uses ct / pt voltage connection with 3P3W (Aron) / 3P4W wiring.
The maximum current (Imax) is 6 A.
It supports two-way RS485 communication compatible with Modbus RTU and DL/T 645-2007.
The active energy accuracy is Class 0.5S.
External switched tariff input with two tariffs by default. No battery, RTC or TOU. For a TOU variant, see DEM3K302.
Official DEM3K series datasheet covering product overview, specifications, wiring and dimensions.
Download PDFTell us your requirements and our team will provide a professional solution and quotation within 24 hours.