≤75 ms Communication Refresh
The controlled specification states an M-Bus communication refresh time of ≤75 ms for applications that require timely meter-side data updates.
DEM2A304 is a single-phase, direct-connected DIN-rail energy meter for 1P2W systems with a maximum current of 100 A and wired M-Bus communication in accordance with EN 13757-3. It is rated 120–230 V with a basic current of 5 A, measures Class 0.5 (Class C) active energy, and operates over −40°C to +70°C. The meter occupies 2P (36 mm) on a standard 35 mm DIN rail and is MID B+D certified by SGS UK. Battery-backed RTC supports four TOU tariffs across eight time periods by default, plus external tariff switching.
MID

The controlled specification states an M-Bus communication refresh time of ≤75 ms for applications that require timely meter-side data updates.
Class 0.5 (Class C) active-energy and Class 1 (Class B) reactive-energy measurement in accordance with IEC 62053-21 and IEC 62053-24.
Two-way M-Bus communication in accordance with EN 13757-3, with default address 1, broadcast address 254 and address range 1–250 at 2400 bps (8E1), so the meter connects directly to an existing M-Bus concentrator loop without protocol conversion.
Battery-backed RTC supports four TOU tariffs across eight time periods by default, combined with external dual-tariff switching through a volt-free digital input.
Supports forward + reverse (absolute value), forward − reverse (algebraic sum), forward-only and reverse-only energy calculation modes for different submetering requirements.
An internal battery maintains RTC timekeeping through supply interruptions, so tariff switching keeps its schedule without relying on mains power.
Solutions for AC/DC charging, billing and charging platform integration.
Explore ApplicationDC/PV monitoring for inverters, storage systems and distributed energy monitoring.
Explore ApplicationBranch metering for buildings, factories, tenants and energy allocation.
Explore ApplicationRack, cabinet and distribution power monitoring for data center operations.
Explore Application| Voltage connection | Direct connection |
| Rated voltage | 120–230 V |
| Voltage tolerance | 0.8 to 1.2 Un |
| Frequency | 50/60 Hz |
| Current connection | Direct connection |
| Basic current (Ib) | 5 A |
| Minimum current (Imin) | 0.15 A (MID) / 0.25 A (IEC) |
| Maximum current (Imax) | 100 A |
| Pulse constant | 1000 imp/kWh |
| Power consumption | ≤2 W / 10 VA |
| Active energy accuracy | Class 0.5 (Class C) |
| Reactive energy accuracy | Class 1 (Class B) |
| Voltage accuracy | ±0.5% |
| Current accuracy | ±0.5% |
| Frequency accuracy | ±0.5% |
| Active power accuracy | ±0.5% |
| Reactive power accuracy | ±1% |
| Communication interface | M-Bus |
| Protocol | M-Bus (EN 13757-3) |
| Communication type | Bidirectional |
| Baud rate | 2400 bps (fixed) |
| Frame format | 8 data bits / 1 stop bit / even parity (8E1) |
| M-Bus address | Default 1, broadcast 254, range 1–250 |
| Refresh time | ≤75 ms |
| Display | LCD 6+2 |
| LCD refresh time | 500 ms |
| Pulse indicator | Red LED |
| Keys | Page / Set |
| IP rating | IP30 |
| OVC (overvoltage category) | Class III |
| Insulation class | Class II |
| Rated impulse voltage | 6kV |
| Installation | 35 mm DIN rail, 2P (36 mm) |
| Wiring system | Direct connection, 1P2W |
| Dimensions (H × W × D) | 36 mm × 94 mm × 62.4 mm |
| Operating temperature | −40°C to +70°C |
| Relative humidity | ≤95%, non-condensing |
| Altitude | ≤2000 m |
| Standards | IEC 62052-11:2020 / IEC 62053-21:2020 / IEC 62053-24:2020 / EN 50470-3:2022 |
DEM2A304 is a single-phase, direct-connected DIN-rail energy meter for 1P2W systems with a maximum current of 100 A and wired M-Bus communication in accordance with EN 13757-3. It is rated 120–230 V with a basic current of 5 A, measures Class 0.5 (Class C) active energy, and operates over −40°C to +70°C. The meter occupies 2P (36 mm) on a standard 35 mm DIN rail and is MID B+D certified by SGS UK. Battery-backed RTC supports four TOU tariffs across eight time periods by default, plus external tariff switching.
M-Bus in accordance with EN 13757-3, bidirectional, 2400 bps fixed, 8 data bits / 1 stop bit / even parity, address default 1 with a range of 1–250 and broadcast address 254.
The maximum current (Imax) is 100 A on a direct connection.
Class 0.5 (Class C) active energy and Class 1 (Class B) reactive energy.
The controlled specification states a communication refresh time of ≤75 ms for the M-Bus communication function. End-to-end system performance also depends on concentrator polling and network configuration.
Yes — battery-backed RTC with four TOU tariffs across eight time periods by default, plus external dual-tariff switching.