Adopt the standard sampling method of 75mV.and adopts RS485 communication for data transmission interaction.YTL DC meter DEM2D series Din-Rail 1P two wires Dual Channel CE Approved OEM Electric Meter
Adopt the standard sampling method of 75mV.and adopts RS485 communication for data transmission interaction.YTL DC meter DEM2D series Din-Rail 1P two wires Dual Channel CE Approved OEM Electric Meter
Type |
DEM2D002 |
DEM2D102 |
DEM2D003 |
DEM2D103 |
Voltage input: |
DC 5V~1000V |
DC 5V~1000V |
DC 5V~1000V |
DC 5V~1000V |
Auxiliary power supply |
85~300V AC or 85-300V DC |
85~300V AC or 85-300V DC |
DC 9-60V |
DC 9-60V |
Current: |
Shunt connection method, the primary side current supports up to 2000A Connection signal :75mV |
Shunt connection method, the primary side current supports up to 2000A Connection signal :75mV |
Shunt connection method, the primary side current supports up to 2000A Connection signal :75mV |
Shunt connection method, the primary side current supports up to 2000A Connection signal :75mV |
Accuracy current: |
0.5% |
0.5% |
0.5% |
0.5% |
Voltage Accuracy |
0.5% |
0.5% |
0.5% |
0.5% |
Active Power Accuracy |
1.0% |
1.0% |
1.0% |
1.0% |
Active Accuracy |
Class 1.0 |
Class 1.0 |
Class 1.0 |
Class 1.0 |
Constant: |
According to 1000imp/kWh, 1.2 times the maximum voltage and current, the pulse width is 1.2ms, corresponding to the current setting |
According to 1000imp/kWh, 1.2 times the maximum voltage and current, the pulse width is 1.2ms, corresponding to the current setting |
According to 1000imp/kWh, 1.2 times the maximum voltage and current, the pulse width is 1.2ms, corresponding to the current setting |
According to 1000imp/kWh, 1.2 times the maximum voltage and current, the pulse width is 1.2ms, corresponding to the current setting |
LCD: |
LCD 6+2 |
LCD 6+2 |
LCD 6+2 |
LCD 6+2 |
Consumption: |
≤8VA ≤0.4W |
≤8VA ≤0.4W |
≤8VA ≤0.4W |
≤8VA ≤0.4W |
Temperature: |
-25~70℃ |
-25~70℃ |
-25~70℃ |
-25~70℃ |
Humidity: |
≤95% |
≤95% |
≤95% |
≤95% |
AC withstand voltage |
4400V/min |
4400V/min |
4400V/min |
4400V/min |
Impulse withstand voltage |
6.4kV - 1.2/50µS waveform
|
6.4kV - 1.2/50µS waveform
|
6.4kV - 1.2/50µS waveform
|
6.4kV - 1.2/50µS waveform
|
Battery |
NO |
YES |
NO |
YES |
Muti-tariff |
NO |
YES |
NO |
YES |
Relay |
NO |
YES |
NO |
YES |
● RS485 communication: used for parameter setting, data reading; DTL645 protocol/Modbus Protocol
● DC metering: using shunt sampling, high measurement accuracy; can measure DC power, current, voltage,
● Alarm function: Over-current alarm: When the current exceeds the CT1 value set by the meter, an alarm event occurs, and the alarm light on the electrical surface panel lights up (yellow light),
At the same time, the value of the corresponding alarm status register will change, and the user can read this register through communication to determine whether an over-current alarm has occurred.
● Display: LCD with backlight ,Support Various parameters display,energy data and Instantaneous parameters
● Firmware upgrade: RS485 local upgrade
Height 90mm
Width 36mm
Depth 73mm
confirms that this user guide has been read;
falling, please do not install, power on, and contact us in time;
with lead. It can be installed directly.
base should be fixed on a solid refractory wall with no corrosive gas in the air;
preferably with copper wire or copper terminal.
Established in 2000, Zhejiang Yongtailong Electronic Co., Ltd. is located in the center of Shanghai, Hangzhou and Suzhou cities. YTL is a professional China YTL EV Charging Electricity Meter 5~1000VDC Din-Rail Installation Suppliers and YTL EV Charging Electricity Meter 5~1000VDC Din-Rail Installation Company. With more than 20 years of energy metering experience, we devote ourselves to providing competitive projects and creating value for customers. YTL was one of the first companies in the domestic market with which had an internal R&D department as well as international sales business. Since our foundation in 2000 we have grown to a manufacturer which complies and meet to many specifications from our national and international partners. At present our export volume makes us a leading company for technology and product export to more than 50 countries throughout the world. With provincial high-tech enterprise R&D center, YTL is the Top 100-enterprise with most investment value in Zhejiang. And“Yongtailong”is the famous brand of Zhejiang. For any new products of customers, we will communicate with customers very professionally, listen to their opinions and give useful suggestions to ensure that excellent quality products are made.
Established In
Employees
Export Country
Design Right Patent
AMI watt-hour meter, which is advanced measurement system, is an important part of smart grid, and its hardware design is precise and powerful. Here's a breakdo...
1. Accurate measurement protects user rightsElectricity meters are the core equipment for electricity metering. Their accuracy may be affected by the external e...
As an important part of smart grid, AMI (Advanced Metering Infrastructure) Watt-hour meter has a bright future and is full of challenges. The following is a det...
There are various types of certifications for electric meters, which aim to ensure that the meters meet the standards and requirements set by different countrie...
1. Efficiency of three-phase power systemsThree-phase electricity is the most common power supply method in the current industrial field. Compared with single-p...
The anti-magnetic field technology in energy meters is a crucial feature designed to ensure accurate and fair energy measurement. As electricity theft methods ...